[/vc_column_text][/vc_column][vc_column width=”1/3″ css=”.vc_custom_1402563338395{margin-top: 62px !important;}”][vc_button title=”View as PDF” target=”_blank” color=”btn-inverse” icon=”wpb_document_pdf” size=”btn-large” href=”http://easypurgeapc.com/wp-content/uploads/2015/06/EASYPURGE-APC-INY-may-2015-ENGLISH.pdf” el_class=”boton-pdf”][/vc_column][/vc_row][vc_row][vc_column width=”1/1″][vc_column_text]

    • USE PURE
    • SHAKE BEFORE USE

1. Keep the same screw speed and the same temperature of last material in production.
Empty the barrel.
2. Load the hopper with virgin material according to Table 5 and added directly onto the material EASYPURGE APC dose, as indicated in the same table.

  • TABLE 5

    Machine size

    Amount ofvirgin materialEASYPURGE APCDose

    50 T

    0.300 Kg 6,0 ml

    100 T

    0.500 Kg

     10,0 ml

    200 T

    1,000 Kg

     20,0 ml

    400 T2,000 Kg

    40,0 ml

    800 T

    4,000 Kg

    80,0 ml

    1000 T

    5,000 Kg

    100,0 ml

    2000 T

    10,000 Kg

    200,0 ml

     

 3. Purge until it starts to come out and stop the machine.
 4. Let react for 2 or 3 minutes and purge with virgin material to remove all traces of color and/or degradated material previously released by EASYPURGE APC.
5. Repeat steps 2, 3 and 4 until the system is completely clean.
6. Start new production. 

  •  